WASTE MANAGEMENT COMPANY

QUALITY | FLEXIBILITY | DURABILITY

GARBAGE AND LINEN

CHUTE INSTALLATION

LINER SECTIONS / SYSTEMS

TM® supplies primary intake liners featuring a fully welded "sloping throat area" at the

Intake door, insuring materials dropeasily to the bottom. Variable height tube liners and frame, complete the sections for each floor. The Standard Chute diameter is 600 mm. Linen systems may upgrade to a 710 mm for bagged laundry. Diameters are available up to 800mm. The system integrates other components for fire rating compliance.Chute systems are both available in Galvanized Steel or Stainless Steel.

FIRE RATED COMPONENTS

All our systems are supplied with a fire sprinkler and fire cut off door, insuring your system is kept in Code compliance. Also, we carry all

integrated Fire Rated components and provide Emergency Service OR certified Preventative Maintenance programs

DOORS

T.M. supplies, certifies, installs & repairs Stainless Steel Chute doors, all of which "Self-Close & Positively Latch" We carry basic

Bottom Hinged Garbage; Disposal; Recycling & SideHinged Linen doors. Some are also used for "Thru the Wall" TTW Ground floor Waste Management Systems. Additionally, we carry a range of specialized & replacement doors.Our Recycling door has a low voltage electrical interlock feature providing superior system access control, integrated with our advanced Control Panel - this system may appeal to projects seeking LEED certification.

INSTALLATION REQUIRMENTS

Chute Diameter

Duct/Slab Opening

0-7 25 mm ND
0-15 40 mm ND
0-25 50 mm ND
0-40 65 mm ND
0-50 75 mm ND
  • Front wall should be constructed after the erection of chute.
  • Provide 10 Amps. MCB, earth, neutral, Single Phase power
    point for exhaust control panel near top most intake level.
  • Provide 600 x 600 mm Access door fixed 200 mm above top
    most intake door.

Provide water connection with isolation valve as per chart given below:

No. of intake
hoppers

Size of water
Riser pipe

(450 mm) 850x650 mm
(600 mm) 800x800 mm
(750 mm) 950x950 mm
(800 mm) 1000x1000 mm
  • 1/2" Ball valve at roof level for sanitation unit.
  • Provide wet riser size 25 mm to 75 mm for firefighting system
    for Total building height outside chute per diagram.
  • Connect fire sprinklers provided by us at top portion through socket by 1/2 " NB pipe on alternate floors starting from top.

GARBAGE ROOM / LINEN

  • Shall be air tight non ventilated room.
  • Provide wall tiles (min 2.0 meter. high) & floor tiles.
  • Floor to have slope towards gully trap and connected to drainage / basement sump.
  • Provide 20 Amp MCB, earth, neutral for cleaning control panel in the Main room.
  • Sufficient Lighting Arrangement.
  • Provide clear min. 2 meter. Wide, outside opening flush door (50 mm) to Main Room.
  • Chute duct slab to be closed after installation of chute.

MAIN ROOM SIZE

GROUND FLOOR

Standard Chute

-

3.0 W x 3.0 L x 2.4 H + Extra area as per number. of container

Segregated Chute

-

4.0 W x 4.0 L x 3.5 H + Extra area based on number. of containers